管道安裝施工現場作業,常易發生觸電事故。要時刻牢記現場施工用電安全技術的要求,以防止現場觸電事故的發生。
①. 施(shi)工(gong)現(xian)場(chang)臨(lin)時(shi)(shi)用電(dian)(dian)(dian)(dian)線(xian)路的(de)(de)架設(she)必須嚴格(ge)(ge)執行(xing)《施(shi)工(gong)現(xian)場(chang)臨(lin)時(shi)(shi)用電(dian)(dian)(dian)(dian)安(an)(an)全技術規(gui)程》的(de)(de)規(gui)定。實行(xing)三(san)級(ji)配電(dian)(dian)(dian)(dian)、二(er)級(ji)保護,每臺設(she)備必須實行(xing)“一(yi)機、一(yi)刀閘、一(yi)漏(lou)電(dian)(dian)(dian)(dian)保護器(qi)、一(yi)刀閘箱”。施(shi)工(gong)用的(de)(de)動力電(dian)(dian)(dian)(dian)源由(you)專業(ye)電(dian)(dian)(dian)(dian)工(gong)負(fu)責(ze)安(an)(an)裝架設(she)并(bing)試運(yun)行(xing)合格(ge)(ge),經驗收交付后使用。項目(mu)經理部應(ying)落實一(yi)個經特種作(zuo)業(ye)安(an)(an)全操作(zuo)培訓(xun)、取(qu)證的(de)(de)電(dian)(dian)(dian)(dian)工(gong)負(fu)責(ze)管理現(xian)場(chang)的(de)(de)臨(lin)時(shi)(shi)用電(dian)(dian)(dian)(dian)工(gong)作(zuo),要求切實做到:“裝”得(de)(de)安(an)(an)全,“拆”得(de)(de)徹底,“檢”查(cha)經常,“修”理及(ji)時(shi)(shi)。其(qi)他人員(yuan)不得(de)(de)亂(luan)動用電(dian)(dian)(dian)(dian)設(she)備和線(xian)路。
②. 施(shi)工(gong)現場(chang)專用(yong)(yong)的(de)(de)(de)中性點(dian)直接接地的(de)(de)(de)電力線(xian)路必(bi)(bi)(bi)須采用(yong)(yong)三(san)相五(wu)線(xian)制,電氣設備的(de)(de)(de)金屬(shu)外(wai)殼必(bi)(bi)(bi)須與專用(yong)(yong)保(bao)護(hu)零線(xian)連接。地下室、潮濕地點(dian)、金屬(shu)容(rong)器內(nei)的(de)(de)(de)施(shi)工(gong)照(zhao)明用(yong)(yong)電必(bi)(bi)(bi)須使(shi)用(yong)(yong)安全電壓,不同的(de)(de)(de)電壓線(xian)路不能混放(fang)在一起,應分開架(jia)設。現場(chang)的(de)(de)(de)動力、照(zhao)明線(xian)路的(de)(de)(de)架(jia)設,不得利用(yong)(yong)樹干、金屬(shu)腳手架(jia)或(huo)其他易晃動的(de)(de)(de)立(li)木代替(ti)電線(xian)桿。
③. 施(shi)工現場所有的移動式電閘箱(xiang),應裝設漏電斷(duan)(duan)路保(bao)護器,不(bu)(bu)得(de)以鋁(lv)絲(si)(si)、銅絲(si)(si)或其他金(jin)屬絲(si)(si)代替保(bao)險(xian)絲(si)(si),并(bing)采取防(fang)雨(yu)、防(fang)火措施(shi)。閘箱(xiang)不(bu)(bu)用時要切斷(duan)(duan)電源,鎖(suo)好閘箱(xiang)。
④. 電(dian)氣(qi)(qi)(qi)機(ji)械設(she)備(bei)(bei)的額(e)定工作(zuo)電(dian)壓(ya)必須(xu)與電(dian)源電(dian)壓(ya)等級相符,其安(an)全裝(zhuang)置(zhi)必須(xu)齊全有效(xiao),嚴(yan)禁(jin)用(yong)獨股導線(xian)、自來(lai)水管道(dao)、暖氣(qi)(qi)(qi)管道(dao)等當(dang)作(zuo)設(she)備(bei)(bei)保護地(di)線(xian)使用(yong)。電(dian)氣(qi)(qi)(qi)機(ji)械設(she)備(bei)(bei)每個(ge)(ge)接(jie)(jie)地(di)點應以單獨的接(jie)(jie)地(di)線(xian)與接(jie)(jie)地(di)干線(xian)相連接(jie)(jie)。嚴(yan)禁(jin)在一(yi)個(ge)(ge)接(jie)(jie)地(di)線(xian)中串(chuan)接(jie)(jie)幾個(ge)(ge)接(jie)(jie)地(di)點。
⑤. 低壓(ya)線(xian)路(lu)裝置中嚴禁利(li)用大(da)地做零(ling)線(xian)供電(dian)。不得借用機械本身(shen)鋼結構做工作(zuo)零(ling)線(xian)。保護零(ling)線(xian)上不得加裝熔(rong)斷器或斷路(lu)設備(bei)。
⑥. 嚴禁(jin)帶電(dian)作業,檢修電(dian)氣設備前必須切(qie)斷電(dian)源(yuan)并在(zai)電(dian)源(yuan)開關上掛(gua)“禁(jin)止合閘、有人(ren)工作”的(de)警告牌。警告牌的(de)掛(gua)、取應有專人(ren)負責。電氣裝置(zhi)遇到跳閘時(shi),不(bu)得強行(xing)合閘。應查(cha)明原因,排除(chu)故障后再行(xing)合閘。
⑦. 發(fa)生(sheng)人身(shen)觸(chu)(chu)電時,應立即(ji)切斷電源,然后對觸(chu)(chu)電者做緊急救護。嚴禁在未切斷電源之前與(yu)觸(chu)(chu)電者接觸(chu)(chu)。