焊(han)接支管(guan)的補(bu)強計算(suan)在GB50316、SH 3059、GB/T 20801、ASME B31.1、ASME B31.3等規(gui)范(fan)中(zhong)均有介紹。焊(han)接支管(guan)的補(bu)強計算(suan)如圖16.9所(suo)示。


圖 9.jpg


  支(zhi)管(guan)軸線(xian)與主管(guan)軸線(xian)斜交的(de)結(jie)構形式(shi),圖(tu)中支(zhi)管(guan)軸線(xian)與主管(guan)軸線(xian)的(de)夾角β應介于(yu)45°~90°之間。主管(guan)為焊接(jie)管(guan)時,焊縫應位于(yu)主管(guan)的(de)斜下(xia)方。


 開孔(kong)補(bu)強面積的計算方法(fa)如下:


式 7.jpg



   補(bu)強面積計算(suan)結果應符合(he)下式規(gui)定:  A2+A3+A4 ≥ A1   (16.13)



  主(zhu)管上多支管的(de)補(bu)強(qiang)(qiang)(qiang)(qiang),應(ying)符合下(xia)列規定:當主(zhu)管上任意(yi)兩個或(huo)兩個以上相(xiang)(xiang)鄰(lin)開孔(kong)(kong)(kong)的(de)中(zhong)心(xin)距小于(yu)相(xiang)(xiang)鄰(lin)兩孔(kong)(kong)(kong)平均(jun)直徑的(de)2倍(bei),其補(bu)強(qiang)(qiang)(qiang)(qiang)范圍重疊(die)時,如圖(tu)16.10所示,這兩個或(huo)兩個以上的(de)開孔(kong)(kong)(kong)必須(xu)按前面(mian)(mian)(mian)的(de)敘述進行(xing)補(bu)強(qiang)(qiang)(qiang)(qiang)計算,并采用(yong)聯(lian)合補(bu)強(qiang)(qiang)(qiang)(qiang)方式進行(xing)補(bu)強(qiang)(qiang)(qiang)(qiang)。采用(yong)聯(lian)合補(bu)強(qiang)(qiang)(qiang)(qiang)時,總補(bu)強(qiang)(qiang)(qiang)(qiang)面(mian)(mian)(mian)積(ji)(ji)不(bu)應(ying)小于(yu)各孔(kong)(kong)(kong)單獨補(bu)強(qiang)(qiang)(qiang)(qiang)所需補(bu)強(qiang)(qiang)(qiang)(qiang)面(mian)(mian)(mian)積(ji)(ji)之(zhi)和,置(zhi)于(yu)兩相(xiang)(xiang)鄰(lin)孔(kong)(kong)(kong)之(zhi)間的(de)補(bu)強(qiang)(qiang)(qiang)(qiang)面(mian)(mian)(mian)積(ji)(ji)至少應(ying)等于(yu)各孔(kong)(kong)(kong)所需補(bu)強(qiang)(qiang)(qiang)(qiang)面(mian)(mian)(mian)積(ji)(ji)之(zhi)和的(de)50%,且(qie)此(ci)兩相(xiang)(xiang)鄰(lin)孔(kong)(kong)(kong)中(zhong)心(xin)距至少應(ying)等于(yu)兩開孔(kong)(kong)(kong)平均(jun)直徑的(de)1.5倍(bei)。在計算補(bu)強(qiang)(qiang)(qiang)(qiang)面(mian)(mian)(mian)積(ji)(ji)時,任何(he)部分截面(mian)(mian)(mian)不(bu)得重復計入(ru)。


圖 10.jpg


  管(guan)(guan)道(dao)開(kai)孔補強的兩種方法:補強圈補強,以(yi)全熔透焊縫(feng)將(jiang)內部(bu)或外部(bu)補強圈與支管(guan)(guan)、主(zhu)管(guan)(guan)相焊;整體補強,增(zeng)加主(zhu)管(guan)(guan)厚(hou)(hou)度(du),或以(yi)全熔透焊縫(feng)將(jiang)厚(hou)(hou)壁支管(guan)(guan)或整體補強鍛件(jian)與主(zhu)管(guan)(guan)相焊。


  采用補強(qiang)圈(quan)補強(qiang)時應(ying)遵守的(de)規(gui)定:采用的(de)鋼材(cai)標準(zhun)抗(kang)拉強(qiang)度(du)(du)Rm≤540MPa;主(zhu)管壁(bi)名義厚(hou)度(du)(du)δn≤38mm;補強(qiang)圈(quan)厚(hou)度(du)(du)應(ying)不大于1.58δn。



工程應用:某管子支管補強設(she)計


  某管子支管補強(qiang)設計見圖16.11,補強(qiang)板的(de)材(cai)料與主管相(xiang)同。補強(qiang)板的(de)長度是支管外徑(jing)的(de)2倍。


圖 11.jpg