一、夾套管材料(liao)的設計
①. 夾套管的內管應采用無縫鋼管,套管可采用無縫鋼管或焊接鋼管。
②. 夾套管(guan)(guan)中與內管(guan)(guan)連接的管(guan)(guan)件(jian)應與內管(guan)(guan)材質(zhi)相同(tong)。
③. 當套管與內管之間溫度差過大(da)或材(cai)質(zhi)不(bu)相同(tong)時,應對(dui)夾套管進行應力(li)分析計算,如兩者熱脹(zhang)差異產(chan)生(sheng)的熱應力(li)超(chao)過許(xu)用(yong)值時內管與套管宜采用(yong)同(tong)種(zhong)材(cai)質(zhi)或線膨脹(zhang)系數相近的材(cai)質(zhi)。
二、夾套(tao)管的(de)安裝(zhuang)
①. 除夾(jia)(jia)套管(guan)(guan)(guan)(guan)(guan)的(de)供給(gei)管(guan)(guan)(guan)(guan)(guan)和回(hui)收管(guan)(guan)(guan)(guan)(guan)外,夾(jia)(jia)套管(guan)(guan)(guan)(guan)(guan)的(de)主體部分(fen)應進(jin)行(xing)預制。管(guan)(guan)(guan)(guan)(guan)夾(jia)(jia)套預制時,應預留調整(zheng)管(guan)(guan)(guan)(guan)(guan)段,其調節(jie)裕量宜為50~100mm,調整(zheng)管(guan)(guan)(guan)(guan)(guan)段的(de)接縫位(wei)置(zhi)必(bi)須避開(kai)外開(kai)口處。內管(guan)(guan)(guan)(guan)(guan)焊縫隱蔽型夾(jia)(jia)套管(guan)(guan)(guan)(guan)(guan),在內管(guan)(guan)(guan)(guan)(guan)焊縫處的(de)套管(guan)(guan)(guan)(guan)(guan)應留150mm長缺口,待內管(guan)(guan)(guan)(guan)(guan)焊縫經100%射線(xian)檢(jian)測,經試壓合格后方可(ke)進(jin)行(xing)隱蔽作(zuo)業。
②. 管(guan)夾(jia)套(tao)經剖切后安裝(zhuang)時,縱向(xiang)焊(han)縫應置(zhi)于易(yi)檢修部位。套(tao)管(guan)與內(nei)管(guan)間的(de)間隙(xi)應均勻,并應按設計要求焊(han)接定位板。定位板不(bu)得妨(fang)礙套(tao)管(guan)與內(nei)管(guan)的(de)伸(shen)縮(suo)。
③. 夾套(tao)(tao)管(guan)(guan)內管(guan)(guan)的試驗(yan)壓(ya)力(li)(li)應按內部或(huo)外部壓(ya)力(li)(li)高者的1.5倍確定(ding),夾套(tao)(tao)管(guan)(guan)套(tao)(tao)管(guan)(guan)的試驗(yan)壓(ya)力(li)(li)應為套(tao)(tao)管(guan)(guan)設(she)計壓(ya)力(li)(li)的1.5倍。被(bei)加(jia)熱管(guan)(guan)道應經無損探傷合格及水壓(ya)試驗(yan)合格后(hou)方可焊接套(tao)(tao)管(guan)(guan)。
④. 導熱油(you)管線的要求(qiu):宜采用(yong)焊接,禁(jin)用(yong)螺(luo)紋連接,禁(jin)用(yong)有縫(feng)鋼管;應采用(yong)對(dui)焊法(fa)蘭(lan);宜采用(yong)鑄鋼高溫閥門(men)。宜采用(yong)柔性石墨纏繞墊片(pian);禁(jin)用(yong)有色金屬(shu)。