1. 雨(yu)水管材料
雨水懸吊管(guan)(guan)(guan)(guan)(guan)和立管(guan)(guan)(guan)(guan)(guan)一般采(cai)用塑料管(guan)(guan)(guan)(guan)(guan)或(huo)鑄(zhu)鐵管(guan)(guan)(guan)(guan)(guan),如(ru)管(guan)(guan)(guan)(guan)(guan)道可能受震(zhen)或(huo)工(gong)藝有特殊要求,應采(cai)用鋼管(guan)(guan)(guan)(guan)(guan)。埋(mai)地雨水管(guan)(guan)(guan)(guan)(guan)可采(cai)用非(fei)金屬管(guan)(guan)(guan)(guan)(guan),但立管(guan)(guan)(guan)(guan)(guan)至檢查井(jing)的管(guan)(guan)(guan)(guan)(guan)段宜采(cai)用鑄(zhu)鐵管(guan)(guan)(guan)(guan)(guan)。
2. 雨(yu)水管(guan)安裝
懸(xuan)(xuan)吊(diao)(diao)式雨(yu)水(shui)管(guan)道的(de)(de)敷(fu)設(she)坡(po)度不得(de)小于0.005,埋地管(guan)道的(de)(de)最(zui)小坡(po)度應(ying)不小于生產廢(fei)水(shui)的(de)(de)最(zui)小坡(po)度。懸(xuan)(xuan)吊(diao)(diao)式雨(yu)水(shui)管(guan)道的(de)(de)長度超過15m,應(ying)安裝檢(jian)查口(kou)或帶(dai)法蘭堵(du)口(kou)的(de)(de)三通,其間距不得(de)大于如下規定:懸(xuan)(xuan)吊(diao)(diao)管(guan)直徑≥150mm、200mm的(de)(de)檢(jian)查口(kou)間距分別為≤15m、≤20m。
3. 雨(yu)水漏(lou)斗的(de)連(lian)接(jie)管應(ying)固定在屋面承(cheng)重結(jie)構上,雨(yu)水漏(lou)斗邊緣與(yu)屋面相接(jie)處(chu)應(ying)嚴(yan)密不漏(lou)。連(lian)接(jie)管管徑設計無要求時(shi),不得小于100mm.
4. 雨(yu)水管安裝后,應做灌水試驗,灌水高度必須到每(mei)根立(li)管最上部的雨(yu)水漏(lou)斗(dou)。灌水試驗持續1小(xiao)時(shi),不滲不漏(lou)為合格。


 
		